Multi-Conductor Cable
Multi-Conductor Cable
Multi-conductor cables can endure harsh environmental conditions, surface abrasion, and even contact with flames. Versatile in application and used in many different applications from small electronics to large factory automation. Physically tough, and can withstand even the most demanding applications.
Jackets and conductors consist of many different insulation compounds such as PVC, PTFE, Kynar, Polyethylene, Polypropylene, Silicone, and Hypalon. Multi-conductor cables come available in individual shielding or overall shielding. Individual shielding can be identified when each wire has some type of shield. Overall shielding is when the shield is applied around all the wires in a group. Shields are available in braid, foil, or both. Foil shields or foil/braid shields are used to ensure signal integrity and electrical performance.
Don’t see the product you are looking for? LAPP Tannehill offers a wide variety of products, some of which may not be online. Contact us or chat with us and we'll help you get exactly what you need.
-
601804CY - LAPP ÖLFLEX® 190CY Shielded Multiconductor Cable - 18 AWG 4 Conductor - GrayPart #: OLF601804CY
Mfg #: 601804CY
Manufacturer: LAPPExtremely oil-resistant flexible power and control cable
SERIES: ÖLFLEX® 190 / 190 CY
CONDUCTOR MATERIAL: Bare Copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Braid
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.39
NOMINAL OD (MM): 9.9
VOLTAGE: 600V
TRAY RATINGS: UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL WTTC
UL STYLE / STANDARD: UL 13, UL 2277
-
601807CY - LAPP ÖLFLEX® 190CY Shielded Multiconductor Cable - 18 AWG 7 Conductor - GrayPart #: OLF601807CY
Mfg #: 601807CY
Manufacturer: LAPPExtremely oil-resistant flexible power and control cable
SERIES: ÖLFLEX® 190 / 190 CY
CONDUCTOR MATERIAL: Bare Copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Braid
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.443
NOMINAL OD (MM): 11.3
VOLTAGE: 600V
TRAY RATINGS: UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL WTTC
UL STYLE / STANDARD: UL 13, UL 2277
-
602002CY - LAPP ÖLFLEX® 190CY Shielded Multiconductor Cable - 20 AWG 2 Conductor - GrayPart #: OLF602002CY
Mfg #: 602002CY
Manufacturer: LAPPExtremely oil-resistant flexible power and control cable
SERIES: ÖLFLEX® 190 / 190 CY
CONDUCTOR MATERIAL: Bare Copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Braid
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.329
NOMINAL OD (MM): 8.4
VOLTAGE: 600V
TRAY RATINGS: UL PLTC-ER, UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, UL WTTC
UL STYLE / STANDARD: UL 13, UL 2277
-
602003CY - LAPP ÖLFLEX® 190CY Shielded Multiconductor Cable - 20 AWG 3 Conductor - GrayPart #: OLF602003CY
Mfg #: 602003CY
Manufacturer: LAPPExtremely oil-resistant flexible power and control cable
SERIES: ÖLFLEX® 190 / 190 CY
CONDUCTOR MATERIAL: Bare Copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Braid
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.341
NOMINAL OD (MM): 8.7
VOLTAGE: 600V
TRAY RATINGS: UL PLTC-ER, UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, UL WTTC
UL STYLE / STANDARD: UL 13, UL 2277
-
221803 - LAPP ÖLFLEX® TRAY II Unshielded Flexible Tray Cable - 18 AWG 3 Conductor - BlackPart #: OLF221803
Mfg #: 221803
Manufacturer: LAPPExtremely oil-resistant and flexible tray cable
SERIES: ÖLFLEX® TRAY II / TRAY II CY
CONDUCTOR MATERIAL: Bare Copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.297
NOMINAL OD (MM): 7.5
VOLTAGE: 600V
TRAY RATINGS: UL ITC-ER, UL PLTC-ER, UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, UL WTTC, Direct Burial (ITC)
UL STYLE / STANDARD: UL 13, UL 1063, UL 1277, UL 1690, UL 2250
-
221804 - LAPP ÖLFLEX® TRAY II Unshielded Flexible Tray Cable - 18 AWG 4 Conductor - BlackPart #: OLF221804
Mfg #: 221804
Manufacturer: LAPPExtremely oil-resistant and flexible tray cable
SERIES: ÖLFLEX® TRAY II / TRAY II CY
CONDUCTOR MATERIAL: Bare Copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.32
NOMINAL OD (MM): 8.1
VOLTAGE: 600V
TRAY RATINGS: UL ITC-ER, UL PLTC-ER, UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, UL WTTC, Direct Burial (ITC)
UL STYLE / STANDARD: UL 13, UL 1063, UL 1277, UL 1690, UL 2250
-
221805 - LAPP ÖLFLEX® TRAY II Unshielded Flexible Tray Cable - 18 AWG 5 Conductor - BlackPart #: OLF221805
Mfg #: 221805
Manufacturer: LAPPExtremely oil-resistant and flexible tray cable
SERIES: ÖLFLEX® TRAY II / TRAY II CY
CONDUCTOR MATERIAL: Bare Copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.346
NOMINAL OD (MM): 8.8
VOLTAGE: 600V
TRAY RATINGS: UL ITC-ER, UL PLTC-ER, UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, UL WTTC, Direct Burial (ITC)
UL STYLE / STANDARD: UL 13, UL 1063, UL 1277, UL 1690, UL 2250
-
221807 - LAPP ÖLFLEX® TRAY II Unshielded Flexible Tray Cable - 18 AWG 7 Conductor - BlackPart #: OLF221807
Mfg #: 221807
Manufacturer: LAPPExtremely oil-resistant and flexible tray cable
SERIES: ÖLFLEX® TRAY II / TRAY II CY
CONDUCTOR MATERIAL: Bare Copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.373
NOMINAL OD (MM): 9.5
VOLTAGE: 600V
TRAY RATINGS: UL ITC-ER, UL PLTC-ER, UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, UL WTTC, Direct Burial (ITC)
UL STYLE / STANDARD: UL 13, UL 1063, UL 1277, UL 1690, UL 2250
-
221809 - LAPP ÖLFLEX® TRAY II Unshielded Flexible Tray Cable - 18 AWG 9 Conductor - BlackPart #: OLF221809
Mfg #: 221809
Manufacturer: LAPPExtremely oil-resistant and flexible tray cable
SERIES: ÖLFLEX® TRAY II / TRAY II CY
CONDUCTOR MATERIAL: Bare Copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.429
NOMINAL OD (MM): 10.9
VOLTAGE: 600V
TRAY RATINGS: UL ITC-ER, UL PLTC-ER, UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, UL WTTC, Direct Burial (ITC)
UL STYLE / STANDARD: UL 13, UL 1063, UL 1277, UL 1690, UL 2250
-
221812 - LAPP ÖLFLEX® TRAY II Unshielded Flexible Tray Cable - 18 AWG 12 Conductor - BlackPart #: OLF221812
Mfg #: 221812
Manufacturer: LAPPExtremely oil-resistant and flexible tray cable
SERIES: ÖLFLEX® TRAY II / TRAY II CY
CONDUCTOR MATERIAL: Bare Copper
CONDUCTOR STRANDING: Stranded
SHIELDING: Unshielded
JACKET MATERIAL: Thermoplastic Polymer
NOMINAL OD (IN): 0.477
NOMINAL OD (MM): 12.1
VOLTAGE: 600V
TRAY RATINGS: UL ITC-ER, UL PLTC-ER, UL TC-ER
STANDARDS/APPROVALS: UL Approved, CSA Approved, CE Approved, UL PLTC, UL WTTC, Direct Burial (ITC)
UL STYLE / STANDARD: UL 13, UL 1063, UL 1277, UL 1690, UL 2250